| Back to Index | ||
| Full set the system | ||
| 1. | Enter [User code] | |
|---|---|---|
| 2. | Press [A] | Exit tone sounds |
| Part set the system | ||
| 1. | Enter [User code] | |
| 2. | Press either [B] or [C] | Exit tone sounds |
| Unset the system | ||
| 1. | Enter [User code] | Entry tone stops |
| Reset system after alarm condition | ||
| 1. | Enter [User code] | |
| 2. | Press [CLEAR/TICK] | |
| Omit a zone | ||
| 1. | As full or part set plus | Exit tone sounds |
| 2. | Press [OMIT/X] | |
| 3. | Press [Zone number to omit] | Zone is omitted |
| 4. | Repeat above two steps as required for addition zones | |
| Change your own user code | ||
| 1. | Enter [User code] | |
| 2. | Press [4] | |
| 3. | Enter existing [User code] | Default codes are [OMIT/X] 002 to [OMIT/X] 008 for codes 2 to 8 and [OMIT/X] [OMIT/X] [OMIT/X] [OMIT/X] for duress code |
| 4. | Enter new [User code] | |
| 5. | Press [CLEAR/TICK] | |
| Test the alarm sounders | ||
| 1. | Enter [User code] | |
| 2. | Press [8] | Sounders should sound |
| 3. | Enter [CLEAR/TICK] to end test | |
| Walk test the detection devices | ||
| 1. | Enter [User code] | |
| 2. | Press [9] | Walk test detectors as required - sounder tone changes to indicate detector active |
| 3. | Enter [CLEAR/TICK] to end test | |
| View the event log | ||
| 1. | Enter [User code] | |
| 2. | Press [5] | |
| 3. | Press [1] for earlier events, [3] for later events | |
| 4. | Press [CLEAR] [CLEAR] to end | |
| Keypad personal attack alarm | ||
| 1. | Press [1] and [3] together | Personal attack alarm generate |
| Back to Index | ||